lux_reduction sensor: report reduction %, not retained factor
The 'Lux reduction' sensor published the retained brightness factor, so it read 100% when nothing was being reduced (0% actual reduction) — the label and value were inverses. Now it publishes the actual reduction: 100 - round(factor*100), so 0% = no dimming, higher = more cut, None when the gate is inactive. Updates the output-sensors spec scenarios to match (71 -> 29, 100 -> 0, adds the gate-inactive None case) and adds a publish-level value test (none existed — the prior scenarios were never enforced in code).
This commit is contained in:
parent
7c565a5f5f
commit
76f04237d7
3 changed files with 43 additions and 16 deletions
|
|
@ -175,31 +175,29 @@ The `ambient_lux` output sensor SHALL read the configured `lux_sensor` entity's
|
|||
- **THEN** `outputs["ambient_lux"]` SHALL be `None`
|
||||
- **AND** the `ambient_lux` sensor entity state SHALL be `unknown`
|
||||
|
||||
### Requirement: Lux reduction sensor exposes the applied factor as a percentage
|
||||
### Requirement: Lux reduction sensor exposes the applied reduction as a percentage
|
||||
|
||||
The `lux_reduction` output sensor SHALL publish `factor × 100` to `hass.data[DOMAIN][entry.entry_id]["outputs"]["lux_reduction"]`, where `factor` is the value computed by the lux gate. A value of `100` means no reduction (curve passes through); `50` means brightness was halved. When the lux gate is inactive (sensor below target or unavailable), the value SHALL be `100`.
|
||||
The `lux_reduction` output sensor SHALL publish the brightness reduction the lux gate is applying, as a percentage, to `hass.data[DOMAIN][entry.entry_id]["outputs"]["lux_reduction"]`. The value SHALL be `100 − round(factor × 100)`, where `factor` is the retained brightness factor computed by the lux gate (`target_lux / current_lux`, capped at `1.0`). A value of `0` means no reduction (curve passes through); `50` means brightness was halved; values approaching `100` mean the lights are almost fully cut. When ambient lux is at or below target, the value SHALL be `0`. When the lux gate is inactive (no sensor configured, sensor unavailable, or `target_lux` is 0), the value SHALL be `None` (the sensor renders `unknown`).
|
||||
|
||||
When the lights were turned off due to lux reduction (factor drove brightness below `min_brightness`), the value SHALL be `0`.
|
||||
|
||||
#### Scenario: Lux reduction shows the applied factor
|
||||
#### Scenario: Lux reduction shows the applied reduction
|
||||
|
||||
- **GIVEN** `target_lux` is 500 and `lux_sensor` reads 700
|
||||
- **WHEN** a curve evaluation tick completes
|
||||
- **THEN** `outputs["lux_reduction"]` SHALL be `71` (rounded from 71.4)
|
||||
- **AND** the `lux_reduction` sensor entity state SHALL be `"71"`
|
||||
- **THEN** `outputs["lux_reduction"]` SHALL be `29` (100 − 71, the retained 71.4% rounded)
|
||||
- **AND** the `lux_reduction` sensor entity state SHALL be `"29"`
|
||||
|
||||
#### Scenario: No reduction shows 100%
|
||||
#### Scenario: No reduction shows 0%
|
||||
|
||||
- **GIVEN** `target_lux` is 500 and `lux_sensor` reads 300
|
||||
- **WHEN** a curve evaluation tick completes
|
||||
- **THEN** `outputs["lux_reduction"]` SHALL be `100`
|
||||
|
||||
#### Scenario: Lights-off due to lux shows 0%
|
||||
|
||||
- **GIVEN** the lux gate drove brightness below `min_brightness`
|
||||
- **WHEN** a curve evaluation tick completes
|
||||
- **THEN** `outputs["lux_reduction"]` SHALL be `0`
|
||||
|
||||
#### Scenario: Gate inactive shows unknown
|
||||
|
||||
- **GIVEN** no `lux_sensor` is configured (or it is unavailable, or `target_lux` is 0)
|
||||
- **WHEN** a curve evaluation tick completes
|
||||
- **THEN** `outputs["lux_reduction"]` SHALL be `None`
|
||||
|
||||
### Requirement: Lux output sensors follow the same dispatcher pattern as existing sensors
|
||||
|
||||
The `ambient_lux` and `lux_reduction` sensors SHALL use the same `SIGNAL_OUTPUTS_UPDATED` dispatcher subscription as the three existing sensors. They SHALL NOT poll. `_attr_should_poll` SHALL be `False`. The dispatcher unsubscribe handle SHALL be tracked via `async_on_remove`.
|
||||
|
|
|
|||