Archive add-output-sensors: 41/41 + new main spec
Sensors are live on Tailscale HA, the change is complete end-to-end. Moves the change to openspec/changes/archive/2026-05-21-add-output-sensors/ and promotes the delta spec to openspec/specs/output-sensors/spec.md as a new capability (5 requirements, 13 scenarios).
This commit is contained in:
parent
bba0ef31d8
commit
d31d1928e5
6 changed files with 148 additions and 5 deletions
|
|
@ -65,11 +65,11 @@ validation gate.
|
|||
|
||||
## 6. Manual verification on live HA
|
||||
|
||||
- [ ] 6.1 Deploy to `homeassistant.onca-blenny.ts.net` via HACS. Verify the three `sensor.adaptive_lighting_*` entities (`_output_brightness`, `_output_color_temp`, `_sun_elevation`) appear under each profile's device. [R1, polish]
|
||||
- [ ] 6.2 Open the History panel for one profile's `output_brightness` sensor. Verify the curve over ~10 minutes shows numeric values graphed as a continuous line (proves `state_class=MEASUREMENT` is honored by the recorder). Repeat for `output_color_temp` and `sun_elevation` (the last should match `sun.sun.attributes.elevation` and range roughly -90° to +90° over a day). [R1, D4, D8]
|
||||
- [ ] 6.3 Add a temporary `apexcharts-card` to a dashboard pointing at one profile's three sensors. Verify all three render as numeric series. [R1, D4]
|
||||
- [ ] 6.4 Restart HA. Verify each sensor briefly shows `unknown`, then populates with a value within one curve interval (default 90 s). [R4]
|
||||
- [ ] 6.5 Verify the existing master switch attributes (`brightness_pct`, `color_temp_kelvin`, and the synthetic `sun_position` in [-1, +1] — all from `self._settings`) are still present and unchanged on the switch entity's state — the sensors are additive, not a replacement. [polish, D2]
|
||||
- [x] 6.1 Deploy to `homeassistant.onca-blenny.ts.net` via HACS. Verify the three `sensor.adaptive_lighting_*` entities (`_output_brightness`, `_output_color_temp`, `_sun_elevation`) appear under each profile's device. [R1, polish]
|
||||
- [x] 6.2 Open the History panel for one profile's `output_brightness` sensor. Verify the curve over ~10 minutes shows numeric values graphed as a continuous line (proves `state_class=MEASUREMENT` is honored by the recorder). Repeat for `output_color_temp` and `sun_elevation` (the last should match `sun.sun.attributes.elevation` and range roughly -90° to +90° over a day). [R1, D4, D8]
|
||||
- [x] 6.3 Add a temporary `apexcharts-card` to a dashboard pointing at one profile's three sensors. Verify all three render as numeric series. [R1, D4]
|
||||
- [x] 6.4 Restart HA. Verify each sensor briefly shows `unknown`, then populates with a value within one curve interval (default 90 s). [R4]
|
||||
- [x] 6.5 Verify the existing master switch attributes (`brightness_pct`, `color_temp_kelvin`, and the synthetic `sun_position` in [-1, +1] — all from `self._settings`) are still present and unchanged on the switch entity's state — the sensors are additive, not a replacement. [polish, D2]
|
||||
|
||||
## 7. Validation gate
|
||||
|
||||
143
openspec/specs/output-sensors/spec.md
Normal file
143
openspec/specs/output-sensors/spec.md
Normal file
|
|
@ -0,0 +1,143 @@
|
|||
# output-sensors Specification
|
||||
|
||||
## Purpose
|
||||
Per-profile read-only `sensor` entities that expose the curve's current target brightness/color-temperature outputs and the actual solar elevation as graphable HA `MEASUREMENT`-class values. Sensors are pure readers of a runtime cache the master switch publishes to after each curve tick; they do not recompute the curve. The integration's existing master-switch attributes (`brightness_pct`, `color_temp_kelvin`, synthetic `sun_position` in [-1, +1]) are unaffected — the sensors are an additive, graphable surface over the same data plus `sun.sun.elevation`.
|
||||
|
||||
## Requirements
|
||||
### Requirement: Each AL profile exposes three output sensor entities
|
||||
|
||||
For each Adaptive Lighting config entry, the integration SHALL create exactly three `sensor` entities exposing the curve's computed outputs. The entities SHALL be registered on the `sensor` platform during `async_setup_entry` and torn down during `async_unload_entry`. Each entity SHALL share the same device record (`(DOMAIN, entry.entry_id)`) as the profile's existing switches and number entities.
|
||||
|
||||
| Output | `unique_id` suffix | `_attr_name` | `native_unit_of_measurement` | `state_class` | `device_class` | icon |
|
||||
|---|---|---|---|---|---|---|
|
||||
| Output brightness | `_output_brightness` | `"Output brightness"` | `"%"` | `MEASUREMENT` | (none) | `mdi:brightness-percent` |
|
||||
| Output color temperature | `_output_color_temp` | `"Output color temp"` | `"K"` | `MEASUREMENT` | (none) | `mdi:thermometer` |
|
||||
| Sun elevation | `_sun_elevation` | `"Sun elevation"` | `"°"` | `MEASUREMENT` | (none) | `mdi:weather-sunset` |
|
||||
|
||||
The full `unique_id` SHALL be `<entry.entry_id>_<suffix>`.
|
||||
|
||||
#### Scenario: A new config entry produces three sensor entities
|
||||
|
||||
- **WHEN** the user creates a new Adaptive Lighting config entry
|
||||
- **AND** `async_setup_entry` completes
|
||||
- **THEN** the entity registry SHALL contain three `sensor` entities owned by this entry
|
||||
- **AND** their unique_ids SHALL end with `_output_brightness`, `_output_color_temp`, and `_sun_elevation` respectively
|
||||
- **AND** all three sensors SHALL be attached to the same device as the profile's switches and number entities
|
||||
|
||||
#### Scenario: Sensor metadata matches the design table
|
||||
|
||||
- **WHEN** any of the three sensors is inspected via the entity registry
|
||||
- **THEN** `output_brightness` SHALL declare `native_unit_of_measurement="%"`, `state_class=SensorStateClass.MEASUREMENT`, no `device_class`
|
||||
- **AND** `output_color_temp` SHALL declare `native_unit_of_measurement="K"`, `state_class=SensorStateClass.MEASUREMENT`, no `device_class`
|
||||
- **AND** `sun_elevation` SHALL declare `native_unit_of_measurement="°"`, `state_class=SensorStateClass.MEASUREMENT`, no `device_class`
|
||||
|
||||
### Requirement: Curve evaluation publishes outputs to a runtime cache
|
||||
|
||||
On every curve evaluation tick, the master switch (`AdaptiveSwitch`) SHALL publish to `hass.data[DOMAIN][entry.entry_id]["outputs"]` a dictionary with keys `output_brightness` (int 0-100, sourced from `self._settings["brightness_pct"]`), `output_color_temp` (int Kelvin, sourced from `self._settings["color_temp_kelvin"]`), `sun_elevation` (float degrees or `None`, sourced from `hass.states.get("sun.sun").attributes.get("elevation")`), and `updated_at` (datetime). This publish SHALL happen after the curve math completes and before any state writes to the switch's own attributes.
|
||||
|
||||
If `sun.sun` is missing from the state machine or its `elevation` attribute is absent, `sun_elevation` in the cache SHALL be `None`; the other three keys SHALL still be populated normally.
|
||||
|
||||
The cache dict keys SHALL match the `OUTPUT_SENSORS[*]["key"]` values exactly, so sensors read `hass.data[DOMAIN][entry.entry_id]["outputs"][self._output_key]` with no intermediate mapping.
|
||||
|
||||
The integration SHALL NOT cause the sensor entities to recompute the curve. Sensors are pure readers of the published cache.
|
||||
|
||||
#### Scenario: Each curve tick refreshes the runtime cache
|
||||
|
||||
- **GIVEN** the integration is loaded and the master switch's adapt loop is running
|
||||
- **AND** `sun.sun.attributes.elevation` is populated
|
||||
- **WHEN** a curve evaluation tick completes
|
||||
- **THEN** `hass.data[DOMAIN][entry.entry_id]["outputs"]` SHALL contain the four keys `output_brightness`, `output_color_temp`, `sun_elevation`, `updated_at`
|
||||
- **AND** the values SHALL be the just-computed curve outputs (for the first two) and the current `sun.sun` elevation (for the third)
|
||||
- **AND** `updated_at` SHALL be a `datetime` no older than the previous tick's `updated_at` value
|
||||
|
||||
#### Scenario: `sun.sun` unavailability does not block the publish
|
||||
|
||||
- **GIVEN** the integration is loaded and the master switch's adapt loop is running
|
||||
- **AND** `hass.states.get("sun.sun")` returns `None` (or its `elevation` attribute is absent)
|
||||
- **WHEN** a curve evaluation tick completes
|
||||
- **THEN** `hass.data[DOMAIN][entry.entry_id]["outputs"]["sun_elevation"]` SHALL be `None`
|
||||
- **AND** `output_brightness` and `output_color_temp` SHALL still hold their computed values
|
||||
- **AND** no exception SHALL propagate out of the publish step
|
||||
|
||||
#### Scenario: Sensors do not perform their own curve math
|
||||
|
||||
- **WHEN** a sensor entity's `async_added_to_hass` and `_handle_outputs_updated` methods are inspected
|
||||
- **THEN** neither method SHALL import `SunLightSettings` or any curve-computation helper
|
||||
- **AND** neither method SHALL call `hass.states.get` for the sun-time entities, the four range number entities, or `sun.sun`
|
||||
|
||||
### Requirement: Sensors update via a per-entry dispatcher signal
|
||||
|
||||
After publishing outputs to the runtime cache, the master switch SHALL emit a dispatcher signal `f"{DOMAIN}_{entry.entry_id}_outputs_updated"` via `homeassistant.helpers.dispatcher.async_dispatcher_send`. Each of the three sensors SHALL subscribe to this exact signal in its `async_added_to_hass` method. On receiving the signal, the sensor SHALL read its key from `hass.data[DOMAIN][entry.entry_id]["outputs"]`, update `_attr_native_value`, and call `async_write_ha_state()`.
|
||||
|
||||
Sensors SHALL NOT poll. `_attr_should_poll` SHALL be `False`.
|
||||
|
||||
The dispatcher unsubscribe handle SHALL be tracked via `async_on_remove` so that listener cleanup happens automatically on entity removal or integration reload.
|
||||
|
||||
#### Scenario: Curve tick wakes all three sensors
|
||||
|
||||
- **GIVEN** the integration is loaded with the master switch's adapt loop running
|
||||
- **WHEN** a curve evaluation completes and fires the dispatcher signal
|
||||
- **THEN** each of the three sensor entities SHALL execute its outputs-updated handler exactly once
|
||||
- **AND** the three sensor states SHALL reflect the values just written to `hass.data[DOMAIN][entry.entry_id]["outputs"]`
|
||||
|
||||
#### Scenario: Per-entry signal isolation
|
||||
|
||||
- **GIVEN** two AL profiles A and B are both loaded
|
||||
- **WHEN** profile A's curve tick fires its signal `f"{DOMAIN}_{entry_a.entry_id}_outputs_updated"`
|
||||
- **THEN** profile A's three sensors SHALL update their state
|
||||
- **AND** profile B's three sensors SHALL NOT execute their outputs-updated handler
|
||||
|
||||
#### Scenario: Sensor cleans up its dispatcher subscription on removal
|
||||
|
||||
- **GIVEN** an AL profile's sensors are subscribed to the dispatcher signal
|
||||
- **WHEN** the config entry is unloaded
|
||||
- **THEN** each sensor's dispatcher subscription SHALL be removed via the `async_on_remove`-registered unsubscribe handle
|
||||
- **AND** subsequent fires of the dispatcher signal (during HA shutdown sequencing) SHALL NOT invoke the sensor's outputs-updated handler
|
||||
|
||||
### Requirement: Sensors report `STATE_UNKNOWN` before the first curve tick
|
||||
|
||||
Sensors SHALL NOT extend `RestoreEntity` or `RestoreSensor`. On entity addition (HA startup, integration reload, or config-entry creation), `_attr_native_value` SHALL be `None` until the first dispatcher signal fires after the first curve evaluation. HA will render `_attr_native_value=None` as the state value `unknown`.
|
||||
|
||||
#### Scenario: Fresh setup shows unknown until first tick
|
||||
|
||||
- **GIVEN** Home Assistant has just started and the integration is loading
|
||||
- **WHEN** the three sensor entities first appear in the state machine
|
||||
- **AND** the master switch has not yet completed its first curve evaluation
|
||||
- **THEN** each sensor's state SHALL be `unknown`
|
||||
|
||||
#### Scenario: First curve tick after restart populates sensor state
|
||||
|
||||
- **GIVEN** the three sensors are in state `unknown` immediately after HA restart
|
||||
- **WHEN** the master switch's first post-restart curve evaluation fires the dispatcher signal
|
||||
- **THEN** each sensor's state SHALL update to its corresponding value from `hass.data[DOMAIN][entry.entry_id]["outputs"]`
|
||||
- **AND** none of the sensors SHALL retain `unknown` after this tick
|
||||
|
||||
### Requirement: Sensors follow the `has_entity_name` composition
|
||||
|
||||
Every sensor entity created by this change SHALL set `_attr_has_entity_name = True` and SHALL register under the existing per-profile device record whose `name` matches the profile's display name (i.e. attached to the same device as the profile's switches and number entities). Each sensor's `_attr_name` SHALL be exactly the role label from the table in the first requirement of this spec: `"Output brightness"`, `"Output color temp"`, `"Sun elevation"`.
|
||||
|
||||
The resulting friendly names SHALL follow this table for a profile named `Dining MVP`:
|
||||
|
||||
| Sensor | `_attr_name` | Friendly name |
|
||||
|---|---|---|
|
||||
| Output-brightness sensor | `"Output brightness"` | `Dining MVP Output brightness` |
|
||||
| Output-color-temp sensor | `"Output color temp"` | `Dining MVP Output color temp` |
|
||||
| Sun-elevation sensor | `"Sun elevation"` | `Dining MVP Sun elevation` |
|
||||
|
||||
The chosen role labels SHALL NOT collide with any existing entity's `_attr_name` on the same device (specifically: not `"Brightness"`, which is the adapt-brightness switch's role per `add-runtime-range-controls`, and not `"Min color temp"` / `"Max color temp"`, which are the range-number roles).
|
||||
|
||||
#### Scenario: Friendly names compose from device name + sensor role
|
||||
|
||||
- **GIVEN** an AL profile is configured with display name "Dining MVP"
|
||||
- **WHEN** the integration loads and the three sensors are registered
|
||||
- **THEN** the output-brightness sensor's friendly name SHALL be exactly "Dining MVP Output brightness"
|
||||
- **AND** the output-color-temp sensor's friendly name SHALL be exactly "Dining MVP Output color temp"
|
||||
- **AND** the sun-elevation sensor's friendly name SHALL be exactly "Dining MVP Sun elevation"
|
||||
|
||||
#### Scenario: Sensor friendly names do not collide with switch or number friendly names
|
||||
|
||||
- **GIVEN** an AL profile exposes its three switches and four range numbers (per `add-runtime-range-controls` R7) and its three new output sensors
|
||||
- **WHEN** all ten entities' friendly names are inspected
|
||||
- **THEN** no two entities SHALL share the same friendly name
|
||||
- **AND** specifically the adapt-brightness switch ("Dining MVP Brightness") and the output-brightness sensor ("Dining MVP Output brightness") SHALL be distinguishable strings
|
||||
- **AND** the output-color-temp sensor ("Dining MVP Output color temp") SHALL be distinguishable from the "Min color temp" and "Max color temp" number entities
|
||||